AYK-03W Alarm Control Module

Item No.: 02672
UWKS dervice is designed according to SOLAS XT-12, water lever mnonitor and alarm of balk carier cargo hold, ballast tank and close dry space. The characters of this system are easily operation, convenient for maintain and running safe stability.
Description
Description
AYK-03W Alarm Control Module
This dervice is designed according to SOLAS XT-12, water lever mnonitor and alarm of balk carier cargo hold, ballast tank and close dry space. The characters of this system are easily operation, convenient for maintain and running safe stability. When the water ingress bulk carrier cargo hold, ballast tank I close dry space ete and reaching the limited water level, the system will give alarm.
The device consists of main alarm control panel in ECR, extended alarm panel on the bridge, safety barrier and water ingress detection sensor located on gauge point etc. The detector is to be fitted in the aft part of each cargo hold, as close to the center line as practicable, and arranged to provide visual & le pre-alarm signal when the water depth in the cargo hold reaches 0.5m; the device provides visual & audible main alarm signal when the water depth cargo hold reaches 2m but not more than 15% of hold depth; the device provides audible & visual alarm signal when the water level in dry space or pace reaches 0.1m above bottom space; the device provides audible & visual alarm signal when the water level in ballasts water tank, collision bulkhead s 10% of the volume of the tank.

Specification:

1.Alarm Control Module:
Model: AYK-03 W
No. of channels: 10
Outline size: 160 × 80 x 140 mm
Power source: DC 24V
Power consumption: 5.0W (DC 24V)
Input signals: NC or NO switch signal
Time delays: 0~99 seconds
Channel output: 10 channels extended alarm output, NC or NO
Horn output: Relay SPDT dry contact output AC 220V 2A
Accept horn: By means of push button on the front, or externally Accept flash: By means of push button on the front, or externally
Test function: by pushing both accept push buttons
Other function: malfunction alarm and dimming function

2. Main alarm panel
Power source: AC 220V 50/60HZ.
Stand-by power voltage: DC 24V
Number of detection point: No limits
Accuracy of detecting: ‡ 20mm
Function:
Audible main & pre-level alarm for individual detection
Multichannel LED flash alarm
Buzzer alarm
Main & pre power supply
AC/DC power fail alarm & alarm reset
Lamp & horn test
Water ingress detection sensor fail alarm
Input alarm time delay 0-99s (adjustable)
Dimming function
Flash stop, horn stop and overriding
Multi-way extended alarm signal output
RS485port alarm signal output (to VDR)
Mounting method: wall or console mounting type
3. External alarm panel
Power supply: DC 24V
Function: Audible main & pre-level alarm for individual detection
Multichannel LED fash alarm
Common alarm buzzer
Lamp test
Dimming function
Mounting method: wall or console mounting type

4.Water level transmitter (UHC or YSZK-01L or UOK-652 type )
Function:When the level reaches 0.5m and 2.0m alarm point, transmitter circuit
output switch signal (the alarm height can be set as 0.1m or 10% tank height for dry
space and void space). This appropriate contact signal is transmitted to main alarm
panel on which the audible and visual alarm is provided.
Alarm waterline:500+10mm,2000+10mm
Power supply: DC24V
Differential:<10mm
Type: electrode or pressure type
Contact capacity: DC24V 1A
Working temp.:-25℃~70℃
Ex. mark: Ex ia l CT6
Protection: IP68
Send your message to us
ver_code