Specifications(Output current) | 200A | |||
Input | Rated voltage | Single-phase 220VAC、Three-phase 380VAC、Three-phase 440VAC | ||
Input range | Rated voltage±15% | |||
Input frequency | 45~65HZ | |||
Efficiency | ≥87% | |||
Maximum current | Single-phase 220 | <30A | ||
Three-phase 380 | <10A | |||
Three-phase 440 | <9A | |||
Output | Floating voltage | 26.4VDC±0.1V(Can be adjusted according to customer requirements and battery specifications) | ||
Average voltage | 28.2VDC±0.1V(Can be adjusted according to customer requirements and battery specifications) | |||
Average floating charge conversion current |
Rated output current 10%±1A | |||
Regulation accuracy | ±1% | |||
Output ripple and noise | VPP≦300mV | |||
Function | Alarm and protection functions | Input under voltage protection, input over voltage protection, output under voltage warning, output over voltage protection, output short circuit protection, output over current protection, power supply over temperature protection |
||
Standard functions | Public warning, fault passive dry contact port (contact limit specification: 32V / 1A) | |||
Optional functions | Input instructions, work instructions, fault instructions, current regulation | |||
Working environment | Operating temperature | ‐15℃~+55℃ | ||
Storage temperature | ‐25℃~+85℃ | |||
Relative humidity | 0~95%(Non-condensing) | |||
Atmospheric pressure | 70kPa~106kPa | |||
Cooling method | Air-cooled | |||
Standard range | Safety | IEC61000-4-2、IEC61000-4-3、IEC61000-4-4、IEC61000-4-5、IEC61000-4-6、IEC60092-101、IEC60068-2-11 | ||
Conduction, radiation | CISPR16、EN55022 | |||
Certification | CCS Type approval | |||
Others | Size(WxDxH)mm | 316x410x295 | ||
Weight | 26kg | |||
Installation method | Wall mounted installation |